GTP- 500M

GTP-500M is an intelligent Controller with GPS. Within the high performance 32 bit CPU, GTP-500M is suited for the harsh industrial environment. It features 3G module, 1 RS-232, 1 RS-485, SD and one I/O expansion bus interface. It can be used in M2M application fields to transfer GPS and data of Modbus device via WCDMA/GPRS. GTP-500M has three functions for different requirement, including RTU function, RMV function and SMS function. Therefore, GTP-500M is an ideal solution for environmental monitoring, remote device management and vehicle monitoring system for M2M applications.

Request For Quotation

    Description

    Applications

    Features

    • Support WCDMA 850/900/1900/2100 MHz frequency
    • Support GPRS 850/900/1800/1900 MHz frequency
    • Intelligent multiport serial to 2G/3G gateway
    • Intelligent 2G/3G Remote Terminal Unit (RTU)
    • Intelligent 2G/3G SMS/Voice alarm controller(SMS)
    • 1 x RS-232 port and 1 x RS-485 port for Virtual COM. 1 x Utility port for
    • Configuration
    • Built-in Watch-dog Function
    • Power Reverse Polarity Protection
    • Power supply +10 VDC ~ +30 VDC
    • Support GPS function

    Software Solutions

    The M2M RTU center software with friendly Graphic interface is to manage the GPRS RTU products easily. Users can monitor the I/O data and status of GPRS RTU devise by the interface on PC. By using the GPRS RTU API tool and M2M RTU center software, any remote monitoring system can be achieved easily and efficiently. For SCADA system, the M2M.OPC server is provided to connect to SCADA by OPC interface.

     

    Easy to Establish GPRS Network Applications
    It is a big headache for engineers to establish the GPRS applications because the dynamic IP management is required. Applying the GT-540 and M2M RTU center software, the dynamic IP addresses can be managed between them. The remote GPRS RTU product would connect to M2M RTU Center automatically. Therefore, all remote GPRS RTU devices can be managed by s single centralized M2M GPRS RTU Center software with a fixed IP address. Moreover, there are M2M API tool and OPC server for engineers to develop the GPRS applications by VB, VC or SCADA development tools conveniently without any IP address management effort.
    Active data transmission
    The GT-540 with active I/O transmission mechanism can raise the communication. Unlike the traditional poll communication, it would transfer the data by the defined time, DI trigger or AI hi/lo alarm. In addition to improve the way of communication, that can also reduce the AP effort.
    Transfer data by e-mail
    Expect for the transferring data by the general communication with the M2M RTU center, users can choose the e-mail mode to send these data by e-mail over GPRS in the fixed time.
    Modbus RTU device connectivity
    The GT-540 is built-in Modbus RTU protocol. That can make any Modbus RTU device connect to the GT-540. By the way of GT-540, Modbus RTU devices can be used in GPRS remote system. The max Modbus RTU device can be connected to the GT-540 is three.
    Simple Local I/O link Control
    There are I/O built-in GPRS RTU devices of ICP DAS. Therefore, these products can be the GPRS I/O devices. Expect for these local I/O data can be sent to the host PC, the I/O link function of them help users to do the simple control in local field. For example: the DI trigger or high/low AI alarm can driver the DO channel.
    Built-in I/O Data Logging
    The GT-540 provides an external SD interface. These local I/O and Modbus data are recorded in SD memory card for one day in a single file.

    Function

    RTU:

    RMV:

    SMS:

    Hardware Specification

    System
    CPU ARM Microprocessor
    WDT(watchdog) Yes
    2G System
    Frequency Band
    850/900/1800/1900 MHz
    Power Class
    Class 4 (2 W @ 850/900 MHz)
    Class 1 (1 W @ 1800/1900 MHz)
    3G System
    Frequency Band
    850/900/1900/2100 MHz
    Power class Class 3(250mW @ WCDMA/HSPA)
    Serial ports
    Utility port (COM1)
    RS-232: TxD, RxD, GND (use for device configuration and debug)
    COM2
    RS-485: D+, D- (use for communication with other devices)
    Baud Rate
    9600 bps and 115200 bps
    Power
    Protection

    Power reverse polarity protection

    Frame Ground Protection
    ESD, Surge, EFT, Hi-Pot
    Required Supply Voltage
    +10 VDC ~ +30 VDC
    Mechanical
    Casing
    Matel
    Dimensions (W x L x H) 117 mm x 137 mm x 58 mm
    Environment
    Operating Temperature -25 ℃ ~ +75 ℃
    Storage Temperature -30 ℃ ~ +80 ℃
    Ambient Relative Humidity
    5 ~ 95% RH, non-condensing

    Ordering Informations

    GTP-500M CR
    Intelligent 2G/3G Controller with GPS(RoHS)

    Datasheet

    gtp-500m_datasheet.pdf

    GTP-500M_User_Manual_EN.pdf

    GTP-500M_quickstart_v100.pdf