I-7520/I-7520A/I-7520R/I-7520AR
|
I-7520: Isolated RS-232 to RS-485 Converter
I-7520A: Isolated RS-232 to RS-422/485 Converter
I-7520R: RS-232 to Isolated RS-485 Converter
I-7520AR: RS-232 to Isolated RS-422/485 Converter
Most industrial computer systems provide standard RS-232 serial ports. Though widely accepted, RS-232 has limited transmission speed, range, and networking capabilities. The RS-422 and RS-485 standards overcome these limitations by using differential voltage lines for data and control signals, which transparently converts RS-232 signals into isolated RS-422 or RS-485 signal with no need to change any hardware or software. The I-7520/I-7520A lets you easily build an industrial grade, long-distance communication system using standard PC hardware.
The design of the isolation between the I-7520 and the I-7520R/AR is different. If the user wants to supply power from the PLC/PC, the I-7520R/AR should be used, otherwise the isolation will be broken. Refer to the I-7000 bus converter manual for detailed information.
Request For Quotation
Description
Features
- Automatic RS-485 Direction Control
- ESD Protection for the RS-232/422/485 Data Line
- Power Input, +10 ~ +30 VDC
- 3000 VDC Isolation Protection on the RS-485 side
- Transmission Speed of up to 115200 bps
- Operating Temperatures, -25 °C ~ +75 °C
- DIN-Rail
Hardware Specifications
Models | I-7520 | I-7520R | I-7520A | I-7520AR | |
Serial Interface | RS-232 | TxD, RxD, GND | |||
RS-422 | – | TxD+, TxD-, RxD+, RxD The RS-422 and RS-485 cannot be used simultaneously |
|||
RS-485 | Data+, Data- | ||||
Transfer Distance | Max. 1,200 m at 9.6 kbps; Max. 400 m at 115.2 kbps (Belden 9841 2P twisted-pair cable, if different cables are used, the transmission distance may change) |
||||
Self-Tuner Asic Inside | Yes | ||||
Speed | 300 ~ 115200 bps | ||||
ESD Protection | Yes | ||||
3000 VDC Isolation on CH1 ~ CH4 | on RS-232 side | on RS-485 side | on RS-232 side | on RS-485 side | |
Connection | RS-232 | 9-Pin Female D-Sub | |||
RS-422/485 | Removable 10-Pin Terminal Block | ||||
LED Indicators | |||||
Power/Communication | Yes | ||||
Power | |||||
Input Voltage Range | +10 VDC ~ +30 VDC (Non-isolated) | ||||
Power Consumption | 1.2 W | ||||
Mechanical | |||||
Casing | Plastic | ||||
Flammability | Fire Retardant Materials (UL94-V0 Level) | ||||
Dimensions (W x H x D) | 72 mm x 118 mm x 35 mm | ||||
Installation | DIN-Rail | ||||
Environment | |||||
Operating Temperature | -25 °C ~ +75 °C | ||||
Storage Temperature | -30 °C ~ +75 °C | ||||
Humidity | 10 ~ 90% RH, non-condensing |
Ordering Informations
I-7520 CR | Isolated RS-232 to RS-485 Converter (RoHS) |
I-7520A CR | Isolated RS-232 to RS-422/485 Converter (RoHS) |
I-7520-G CR | Isolated RS-232 to RS-485 Converter (Gray Cover) (RoHS) |
I-7520A-G CR | Isolated RS-232 to RS-422/485 Converter (Gray Cover) (RoHS) |
I-7520R CR | RS-232 to Isolated RS-485 Converter (RoHS) |
I-7520AR CR | RS-232 to Isolated RS-422/485 Converter (RoHS) |
I-7520R-G CR | RS-232 to Isolated RS-485 Converter (Gray Cover) (RoHS) |